Fireball
Fireball Systems for Warm Climates

Click here for freeze climates

Aqua Alternatives
2131 Middle Drive
Freeland, WA 98249-9516
Toll-free: 1-877-713-7858
petrich@whidbey.com

    All systems are designed to be installed with existing or added standard water heating tanks. They are designed to connect to any existing hot water tank.
No tanks are included with these system prices. In general, systems should be sized to have a minimum of 1 gallon of storage per sq./ ft. of collector area.   Systems 1, 2 and 3 are open-loop systems, meaning that they heat the water that is used throughout the house.  These systems are not designed for freezing conditions.  If there is a freeze, these systems must be drained prior to the freeze.  There are freeze-protective options available and recommended, but they are designed for short-term cold spells only.  If you are not sure which system to get, order the System 3 with all the features.  Figure one panel for every 2-3 people.

Please feel free to call with any questions: (877) 713-7858.

All Kits come with:



System 1

System 1 is for use in completely non-freeze areas.
Can be used in freeze areas when collector is fully drained before freeze.

Prices:

Options:



System 2

System 2  is recommended for a higher level of efficiency in variable weather conditions.
For use in completely non-freeze or light freeze areas.
System 2 can be used in freeze areas when collector is fully drained before freeze.

Includes:

Prices: NOTE: *Recirculation freeze protection is used extensively in mild weather conditions where temperatures occasionally dips below freezing to as low as 20F for a few hours. FULLY DRAIN BEFORE HARD FREEZE (below 30F for 24 hrs) FV01, Freeze Valve Option For Light Passive freeze protection to 30F, FULLY DRAIN BEFORE HARD FREEZE (FV01): $65.00

System 3: SRCC
These systems are Performance Certified

SRCC OG300 Rated System 3 Fireball 20013; 1C50, 2C50, 3C50 and 3C80
(SRCC = Solar Rating and Certification Corporation) TANK NOT INCLUDED
These systems are Performance Certified when installed to SRCC OG300 Specifications and tank sizes. When properly installed and maintained, these systems meet the minimum standards established by SRCC. The SRCC certification does not imply endorsement or Warranty of this product by SRCC.

Includes:

System 3 is for use in completely non-freeze areas. Can be used in freeze areas when collector is fully drained before freeze.
SRCC Reoriented Tilt systems require Parallel flow collectors, (PFL1 or PFR1) to facilitate drainage at an extra charge of $40 per collector. Contact factory for help with this option.

Prices: